Almexa

Industries we serve / Electrical equipment and power

Aluminum strip for transformer windings: alloy, temper and edge

The low-voltage winding of many distribution and dry-type transformers is made from aluminum sheet or strip instead of copper: for the same electrical resistance it needs about 62% more cross-section, but weighs about half as much. The alloy is 1350, the electrical grade, in annealed (O) temper, with a minimum conductivity of 61.8% IACS (The Aluminum Association, Aluminum Standards and Data, Table 16.3). Almexa rolls 1350 in Cuautitlán Izcalli, Mexico, and slits it to your coil width, from 0.0177 to 0.148 in (0.45 to 3.76 mm) thick, from coil up to 48 in (1,219 mm) wide, with a mill test report per lot (technical sheet, October 2026).

Updated 2026-11-24

Aluminum coil on Almexa's slitting line
Alloy
1350, electrical grade; 1050 if your design accepts it
Conductivity
61.8% IACS minimum in 1350-O
Thickness at Almexa
0.0177 to 0.148 in (0.45 to 3.76 mm)
Width
Slit to your size, from coil up to 48 in

Distribution transformers commonly use a coil with a high-voltage winding of copper wire and a low-voltage winding of aluminum sheet. The winding weighs on cost: it is 22% ± 6% of the material cost of a distribution transformer (Olivares-Galván et al., IET Electric Power Applications, 2010).

Aluminum or copper transformer winding?

1350 aluminum against copper as winding conductor
Item1350 aluminumCopper
Conductivity61.8% IACS minimum (O temper)100% IACS, the reference of the scale
Density2.705 g/cm³8.89 g/cm³
Cross-section for the same resistanceAbout 62% moreReference
Conductor mass for the same resistanceAbout 49%Reference
Maximum temperature after a short circuit (IEC 60076-5, oil, class 105 insulation)200 °C; 250 °C if the annealed material meets mechanical requirements250 °C

Conductivity: Aluminum Standards and Data, Table 16.3. 1350 density: The Aluminum Association, August 2018 revision; copper density and temperatures: Olivares-Galván et al. (2010). Section and mass are our own calculation: 1 ÷ 0.618 = 1.62 times the section, and 1.62 × 2.705 ÷ 8.89 = 0.49 of the mass.

A complete transformer with aluminum windings is slightly bulkier but 10 to 12% lighter; the operating temperature is limited by the insulation class, not the metal (Transformers Magazine, vol. 8, no. 4, 2021). Joints need more care than in copper, because aluminum's oxide layer does not conduct.

Which alloy and temper should I order?

1350 in annealed (O) temper. 1350 is the electrical-grade alloy, formerly called EC: it is 99.50% aluminum minimum and limits the elements that lower conductivity. As little as 0.02% manganese or chromium, or 0.1% titanium, lowers it by more than 10% (Olivares-Galván et al., 2010). O is the temper The Aluminum Association publishes with guaranteed minimum conductivity in sheet from 0.006 to 0.125 in, and it is soft enough to wind easily. Almexa also makes 1350 in H12, H14, H16 and H18, and 1050 if your engineering accepts it; the guaranteed minimum conductivity The Aluminum Association publishes is for 1350.

Chemical composition limits of 1350 aluminum, in % (The Aluminum Association, August 2018 revision)
ElementLimit (%)
Silicon0.10 max.
Iron0.40 max.
Copper0.05 max.
Manganese0.01 max.
Chromium0.01 max.
Zinc0.05 max.
Boron0.05 max.
Gallium0.03 max.
Vanadium plus titanium0.02 max.
Others, each0.03 max.
Others, total0.10 max.
Aluminum99.50 min.

Edge, surface and splices

A burr on the strip edge cuts the insulation between turns and causes turn-to-turn shorts, which is why buyers specify burr-free or rounded edges (US patent 4417701, 1983). Almexa slits strip on its 3 slitting lines. If your winder needs a maximum burr, rounded edges, an oil-free surface or splice-free coils, state it in your request and the sales rep confirms what we cover.

Thickness and width at Almexa

1350 aluminum at Almexa: size ranges (technical sheet, October 2026)
FormatThicknessWidth
Coil0.0177 to 0.148 in (0.45 to 3.76 mm)6.30 to 48 in (160 to 1,219 mm)
StripWithin the coil rangeTo your size; the minimum depends on thickness
Sheet0.0197 to 0.148 in (0.5 to 3.76 mm)11.97 to 48 in, up to 144 in long

Coils ship with a 20 in (508 mm) inside diameter and a 39 to 46 in outside diameter. The European standard for electrotechnical sheet and strip, EN 14121, covers 0.20 to 150 mm: gauges below 0.45 mm we do not roll yet. With the equipment being installed at the plant, the minimum will drop to 0.3 mm by the end of 2027.

Standards in Mexico

NOM-002-SEDE/ENER-2014, reaffirmed on November 15, 2024, sets minimum efficiency for distribution transformers with losses corrected to 85 °C; it does not require copper or aluminum. Pole-mounted and substation transformers follow NMX-J-116-ANCE-2017 and dry-type units NMX-J-351-1-ANCE-2021. If your customer's specification calls for a particular conductor, send it with your request.

Quality and origin

Almexa runs an ISO 9001:2015 quality system certified by Intertek; every lot ships with a mill test report of chemistry and mechanical properties. If you need measured conductivity on the report, ask when you request a quote and the sales rep confirms whether it can be done. The metal is cast and rolled in Mexico: under current USMCA rules of origin, Almexa products meet the regional content the agreement requires; the qualification of the finished transformer is confirmed by your customs broker.

What to send for a quote

  • Alloy and temper, for example 1350-O.
  • Minimum conductivity and whether it must be on the mill test report.
  • Thickness and width, with tolerances.
  • Edge condition: maximum burr or rounded edge.
  • Inside and outside diameter, or maximum coil weight, and whether you accept splices.
  • Tons per month and per delivery, and your customer's reference standard.

Product sheets, guides and tools

Sources

Size ranges and tempers: Almexa technical sheet, October 2026. Sources consulted on November 24, 2026.

Frequently asked questions

Which aluminum is used for transformer windings?

1350, the electrical-grade alloy, in annealed (O) temper, with a minimum conductivity of 61.8% IACS per The Aluminum Association. Almexa rolls it as coil and slits it to your coil width, from 0.0177 to 0.148 in thick, with a mill test report per lot.

Aluminum or copper transformer winding?

Aluminum needs about 62% more cross-section for the same resistance, but the conductor weighs about half, and the complete transformer ends up slightly bulkier and 10 to 12% lighter (Transformers Magazine, 2021). Copper conducts better and its joints are simpler. Your transformer design makes the call.

What is the conductivity of 1350 aluminum?

In annealed (O) sheet from 0.006 to 0.125 in, 61.8% IACS minimum at 20 °C, per Table 16.3 of The Aluminum Association's Aluminum Standards and Data.

Does Almexa make aluminum strip thinner than 0.45 mm?

Not yet. Today it rolls from 0.0177 to 0.148 in (0.45 to 3.76 mm). With the equipment being installed at the plant, the minimum will drop to 0.3 mm by the end of 2027.

Have a spec in hand? Quote it with the mill.

Request a quote
Request a quote